Cisco Cisco 1 GHz GainStar Node Installation Guide

Page of 73
 
Installation and Configuration 
 
 
 
18 
 
To Install the Housing in a Pedestal 
Complete the following steps to install the housing on a pedestal. 
1  Drill two 3/8” holes in the mounting plate with 127 mm or 215.9 mm distance. 
The thickness of the metal plate is 10 to 15 mm. 
2  Lift the housing to the proper position on the wall or box. 
3  Align the pedestal mounting holes on the bottom of the housing with the two 
holes drilled in the metal plate and insert the bolts into the two threaded 
mounting holes. 
 
 
4  Using a ½-inch torque wrench, tighten the pedestal clamp bolts from 6.8 Nm to 
9.0 Nm. 
5  Connect the coaxial cable to the pin connector according to connector 
manufacturer specifications. 
6  Proceed to Installing the Accessories.