System Power 
System Power (44 to 90 VAC) 
The GainStar Line Extender draws AC power from the coaxial cable. This AC power 
comes from an external AC power supply. 
    CAUTION: 
RF connectors and housing seizure assemblies can be damaged if 
AC shunt power directors are not removed from the GainStar Line 
Extender before installing. 
Power can come from the input or output ports, and each GainStar Line Extender 
can pass or block AC power flow on any port without affecting the RF continuity. 
However, at least one port must pass AC power to bring power into the GainStar 
Line Extender. 
To set the power direction, install AC shunt power directors for the ports through 
which you wish to pass AC. 
Note: A red AC shunt power director is included in the unit. The red shunt is used 
to activate the port that supplies power. The red shunt should be removed before 
installing or removing the RF module from the housing. 
    CAUTION: 
RF connectors and housing seizure assemblies can be damaged if 
AC shunt power directors are not removed from the GainStar Line 
Extender before installing or removing the GainStar Line Extender 
module from the housing. 
Before powering up the GainStar Line Extender, make sure all accessories are 
installed and properly seated. 
Important: The Main, Aux and RF input ports are the RF/ Power Ports. 
 
 
Main 
Aux 
RF Input Port