Cisco Cisco 1 GHz GainStar Node Installation Guide

Page of 73
 
 
Balancing and Setup 
 
37 
 
 
Complete the following steps to select the proper reverse equalizer value. 
1  Connect the test point probe to the reverse output test point. 
 
2  Compare the calculated tilt with the design tilt (on the design print). 
3  Is the reverse output tilt within ± 0.5 dB of the design tilt? 
 
If yes, proceed to the next section. 
 
If the output tilt is more than the design tilt, replace the reverse EQ with a