Cisco PowerKEY CableCARD Module 802 Technical References

Page of 74
 
Chapter 2    M-Card-Related Diagnostic Screens 
 
 
 
16 
78-4015203-01 Rev D 
Dec and Enc Settings 
 
Field and 
Link Names 
Description 
Possible Values 
CID 
Channel ID of the selected 
stream 
 
[Integer > 1] 
Dec 
Displays the decryption settings 
present in the decrypt control 
register 
 
Decryption settings 
Example: DES/3DES 
 
Disabled
—no decryption settings 
Enc 
Displays the encryption settings 
present in the encrypt control 
register 
 
Encryption settings 
Example: DES/3DES 
 
Disabled
—no encryption settings 
 
 
Xport Driver Stats 
 
Field and 
Link Names 
Description 
Possible Values 
BMM 
The BMM channel number 
 
[Integer > 0] 
QF 
The number of packets dropped 
because the application queue is 
full  
 
[Integer > 0] 
BF 
The number of packets dropped 
because the circular buffer is full  
 
[Integer > 0] 
Cor 
The number of corrupted 
packets detected by the Xport 
ISR (Interrupt Service Routine) 
 
[Integer > 0] 
Sent 
The number of events sent to the 
application  
 
[Integer > 0] 
Read 
The number of reads performed 
by the application  
 
[Integer > 0]