Installing  a  DC  or  DC/EQ  Module  in  a 
Multimedia Stretch Tap 
Installation Instructions 
Overview 
Introduction 
The family of Multimedia Stretch™ Taps consists of the 
Multimedia Stretch Tap (MST), Surge-Gap™ Stretch Tap 
(SGST), and Multimedia Stretch Tap-Technician Access 
(MST-TA). The tap circuit board requires a plug-in 
directional coupler (DC) module to set the tap loss value and 
allow RF signals to pass through the tap. The module value is 
selected for each installation to provide the proper RF level 
output from the subscriber tap ports. 
A directional coupler/equalizer (DC/EQ) module can be 
used instead of a DC. The DC sets the tap value, while the EQ 
controls the output tilt to the drop cables. Neither action by 
the DC/EQ has any effect on the feeder cable signal. The 
DC/EQ can equalize the tap port from 5 MHz to 1 GHz in 
steps of 3 dB from 3 to 18 dB. 
Purpose 
The information in this document will assist technicians in 
correctly positioning the stretch tap DC or DC/EQ module 
on the Multimedia Stretch Tap circuit board. 
 
Overview, Continued 
Scope 
The information in this document applies to the Multimedia 
Stretch Tap, Surge-Gap Stretch Tap, and Multimedia Stretch 
Tap-Technician Access. It does not apply to other taps, such 
as the Flexible Solutions Tap. 
This document is intended for authorized service personnel 
who have experience working with similar equipment. The 
service personnel should have appropriate background and 
knowledge to complete the procedures described in this 
document. 
Qualified Personnel 
Only appropriately qualified and skilled service personnel 
should attempt to install, operate, maintain, and service this 
product. 
 
WARNING: 
Allow only qualified and skilled personnel to install, 
operate, maintain, and service this product. Otherwise, 
personal injury or equipment damage may occur. 
Related Publications 
You may find the following publications useful as you 
implement the procedures in this document. 
  Multimedia Stretch Tap Installation and Operation Guide, 
part number 562384 
  Surge-Gap Stretch Tap Installation and Operation Guide, 
part number 4014132 
  Multimedia Stretch Tap-Technician Access Installation and 
Operation Guide, part number 590212 
Installing the Module
 
The proper orientation of the DC or DC/EQ module depends 
on the intended direction of signal flow. The following 
instructions include two options: 
  Option 1 makes the lower left tap port the signal input 
(See Option 1 diagrams). 
  Option 2 makes the lower left tap port the signal output 
(See Option 2 diagrams). 
Choose the appropriate option based on the direction of 
signal flow desired at the tap. 
To Install the DC or DC/EQ Module 
Follow these steps to install the module. 
1.
  Locate the directional coupler socket on the tap circuit 
board. 
2.
  Position the module to correspond with the direction of 
the RF signal flow direction as shown in Option 1 or 
Option 2. 
3.
  Carefully plug the module into the socket. Be sure that 
all pins on the module align with the corresponding 
holes in the directional coupler socket. 
4. 
Refer to the Multimedia Stretch Tap Installation and 
Operation Guide
part number 562384 for additional setup 
instructions.