Cisco Multimedia Stretch Tap Technician Access Installation Guide
Chapter 2 Installing the Tap
28
590212 Rev G
6 Place the faceplate on the tap housing. Push firmly on the faceplate to seat it in
the housing.
7 Remove the grounding wire assembly.
8 Using a 3/8-in. wrench, tighten the four bolts from 50 in-lb to 60 in-lb (5.6 N-m to
8 Using a 3/8-in. wrench, tighten the four bolts from 50 in-lb to 60 in-lb (5.6 N-m to
6.8 N-m).
9 Optional: Affix the circular "IN" signal direction decal on the faceplate near the
input port.
Note: The input port can be any of the 3 ports, depending on the configuration of
the plug-in DC or DC/EQ and whether the tap is mounted in a pedestal or on a
strand. Refer to Installing Optional Modules (on page 23).
Note: The input port can be any of the 3 ports, depending on the configuration of
the plug-in DC or DC/EQ and whether the tap is mounted in a pedestal or on a
strand. Refer to Installing Optional Modules (on page 23).
10 Proceed to Connecting Coax Drop Cables (on page 29).