Cisco Model 8653-SU Addressable Transmitter Installation Guide

Page of 78
 
 
Installation Procedure 
590212 Rev G 
39 
 
 
Using an Allen-head wrench, torque the two recessed Allen-head screws 
from 30 in-lb to 40 in-lb (3.4 N-m to 4.5 N-m). 
 
5  Attach the coax cable to the MST-TA drop ports as desired. Make sure to tighten 
to the manufacturer's recommended torque specification, usually 30 in-lb (40 N-
m). 
Note: Provide strain relief for the coax cable drop per manufacturer's 
recommendation. 
 
CAUTION: 
Avoid damage to this product. Before installing any terminators, make sure 
AC is not present on the drop ports.
 
6  Insert the twisted pair wire leads through the perforated holes and through the 
gel. The ground wire must be connected to the GND terminal, and the hot wire 
must be connected to the HOT terminal.