Cisco Addressable Multimedia Stretch Tap Installation Guide

Page of 78
 
 
Description of the Multimedia Stretch Tap - TA 
590212 Rev G 
 
Description of the Multimedia Stretch Tap - TA 
The Multimedia Strech™ Tap - Technician Access (MST-TA) is available in a range 
of port configurations and tap values. Interchangeable directional couplers (DCs) 
facilitate changing tap values to equalize the RF plant. 
The faceplate has a technician access panel, which allows access to the positive 
temperature coefficient resistors (PTCs) on the circuit board. In networks where a 
twisted pair wire is needed, the technician access panel can be completely removed 
and the Twisted Pair module added. 
Components 
The tap consists of the following: 
 
9-inch housing 
 
Faceplate with technician access panel 
 
Optional modules 
Directional coupler (DC) 
Directional coupler/equalizer (DC/EQ) 
Positive temperature coefficient resistor (PTC) 
Twisted Pair module 
Features 
The tap has the following important features: 
 
Patented Connection Beam AC/RF bypass allows for removal of the tap 
faceplate without interrupting downstream customer service. 
 
New cable provides a high current (12 A) through rating to allow for passing the 
additional power required for telephony services. 
 
Power passing is selectable on each drop, allowing AC power to flow to a 
subscriber’s telephone interface unit where needed.  
 
9-inch housing spans the typical gap left in the feeder cable after removing old 
taps. This allows for tap upgrades without adding splices or extension 
connectors to the feeder cable. 
 
A plug-in directional coupler sets the tap value. 
 
The technician access panel allows for easy PTC installation. 
 
Twisted Pair module allows for twisted pair wire drop powering.