Cisco Multimedia Stretch Tap Technician Access Data Sheet

Page of 7
Surge-Gap Stretch Taps 
 
4
 
 
Specifications, continued 
 
2-Way Surge-Gap Stretch Tap 
 
 
 
Tap Value 
  Freq. 
4 dB 
8 dB 
11 dB 
14 dB 
17 dB 
20 dB 
23 dB 
26 dB 
29 dB 
 MHz  Mean Max Mean  Max Mean Max Mean Max Mean Max Mean Max Mean  Max Mean Max Mean Max
5 - - 3.4 3.8 1.9 2.4 1.2 1.7 0.8 1.3 0.8 1.3 0.8 1.3 0.8 1.3 0.8 1.3 
40 - - 3.2 3.7 1.5 1.9 0.9 1.4 0.6 1.1 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 
50 - - 3.2 3.7 1.5 1.9 0.9 1.4 0.6 1.1 0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0 
450 - - 4.1 4.5 2.3 2.9 1.6 2.1 1.4 2.0 1.2 1.7 1.2 1.6 1.2 1.6 1.2 1.6 
550 - - 4.0 4.3 2.4 3.0 1.7 2.2 1.5 2.0 1.3 1.7 1.3 1.6 1.3 1.8 1.3 1.8 
750 - - 3.7 4.6 2.4 3.5 1.8 2.3 1.6 2.0 1.3 1.8 1.4 1.8 1.4 1.8 1.3 1.8 
870 - - 5.0 4.8 2.5 3.6 2.0 2.6 1.8 2.4 1.4 1.9 1.5 1.9 1.5 1.9 1.5 1.9 
Insertion 
Loss 
(dB) 
1000 -  - 4.7 5.2 2.9 3.6 2.0 2.6 1.8 2.4 1.4 1.9 1.3 1.9 1.3 1.9 1.3 1.9 
Tap Loss 
Tolerance 
(±1 dB) 
40 
50 
450 
550 
750 
870 
1000 
1.0 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.3
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.2
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.2
 
1.2
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
1.0
 
Tap Port 
Return 
Loss 
(dB, min) 
5-1000 16
 
16
 
16
 
16
 
16
 
16
 
16
 
16
 
16
 
In / Out 
Return 
Loss 
(dB, min) 
10 
50 
750 
870 
1000 
14 
15 
15 
15 
15 
15 
14 
15 
15 
15 
15 
15 
14 
15 
15 
15 
15 
15 
14 
15 
15 
15 
15 
15 
14 
15 
15 
15 
15 
15 
14 
15 
15 
15 
15 
15 
14 
15 
15 
15 
15 
15 
14 
15 
15 
15 
15 
15 
14 
15 
15 
15 
15 
15 
Tap-to-Tap 
Isolation 
(dB, min) 
750 
1000 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
18 
Out-to-Tap 
Isolation 
750 
1000 
18 
18 
18 
20 
20 
20 
20 
22 
22 
22 
22 
22 
25 
25 
25 
25 
25 
25 
35 
35 
35 
35 
35 
35 
Above performance specifications are with standard DC plug-in installed.  For specifications with DC/EQ or DC/RW plug-ins, refer to the data 
sheets for those products. 
 
 
 
 
 
 
 
 
 
 
Unless otherwise noted, specifications reflect typical performance and are referenced to 68
°F (20°C).  Specifications are based 
upon measurements made in accordance with SCTE/ANSI standards (where applicable), using standard frequency assignments.