Cisco Model 8653-SU Addressable Transmitter Data Sheet
Surge-Gap Stretch Taps
3
Specifications
Dimensions
2-, 4-, 8-way: 3.5 in. H x 9 in. W x 3.5 in. D (88.9 mm H x 228.6 m W x 88.9 mm D)
Mechanical
•
2-, 4-, 8-way: 3.5 in. H x 9 in. W x 3.5 in. D (88.9 mm H x 228.6 m W x 88.9 mm D)
Mechanical
•
AL360T housing with powder paint coating and aluminum end plugs for environmental protection
•
Sealed and swaged extended F-ports for enhanced resistance to moisture ingress
•
Nickel-plated brass F-ports to ensure a corrosion-resistant drop interface
•
Versatile housing design permits aerial, pedestal, or MDU mounting schemes
• Operating
temperature
from -40°C to +60°C
•
EMI shielding minimum 100 dB
•
Pressure tested at 10 psi for 60 seconds under water
Electrical Specifications
•
•
Thru Continuous current 12
amps
-
60/90
V
AC
• Current
limiting
250
mA
@
60°C,
per
drop
• Surge
Resistance
− Input / Output ports - (combo wave) 6 kV
− Tap ports (ring wave)
6 kV
• Impedance 75
ohm
•
Hum Modulation @ 10 Amps (typical)
65 dB (5 - 10 MHz)
70 dB (11 - 1000 MHz)
70 dB (11 - 1000 MHz)
AC/RF Bypass Switch Performance
•
•
System
Open
Circuit
Time 0
ms
•
Contact
Resistance 10
mOhms
max
• Current and voltage Carrying
12 A, 60/90 V AC
•
RF
Frequency
Range
5
to
1000
MHz
• Operating Temperature -40ºC
to
+60ºC
Standards Compliance
Scientific-Atlanta’s Surge-Gap Stretch Taps meet or exceed the following industry standards:
Scientific-Atlanta’s Surge-Gap Stretch Taps meet or exceed the following industry standards:
Safety
• EN 50083-1/EN 60065
• EN 50083-1/EN 60065
• UL 60960-1
Mechanical
•
Mechanical
•
ANSI / SCTE 01 1996 - F-port interface specification
•
ANSI / SCTE 91 2004 - entry port interface specification
Emissions
•
•
FCC - Part 76, Subpart K
• EN
50083-2
Environmental
•
•
ASTM G 53 - weathering specification
•
ASTM B 117 - salt spray specification
•
ASTM D 3170 - chip resistance specification
•
ASTM G 21 - fungus growth rate of zero
•
EN 60529 IP 68
5 MHz
550 MHz
750 MHz
1 GHz
Short Circuited
Insertion Loss (dB)
Insertion Loss (dB)
0.1 Max
0.05 Mean
0.4 Max
0.3 Mean
0.5 Max
0.4 Mean
0.7 Max
0.6 Mean
Short Circuited
Return Loss (dB)
Return Loss (dB)
40 Max
53 Mean
16 Max
18 Mean
16 Max
17 Mean
14 Max
15 Mean
Unless otherwise noted, specifications reflect typical performance and are referenced to 68
°F (20°C). Specifications are based