Cisco Cisco D9859 Advanced Receiver Transcoder Installation Guide
Chapter 5 Web GUI Setup and Monitoring
256
Password Complexity
Description
No Checking
There are no restrictions on passwords.
Note: A minimum of one character is required.
Note: A minimum of one character is required.
Minimal Checking
A password must comply with the following
requirements:
requirements:
It cannot contain username or reversed username.
It cannot contain any of the following strings: cisco,
sciatl, ocsic, Itaics, atlsci, icslta, or any string
achieved by full or partial capitalization of letters.
sciatl, ocsic, Itaics, atlsci, icslta, or any string
achieved by full or partial capitalization of letters.
No letter is repeated more than three times in a row.
Must contain a minimum of four characters.
Full Complexity Checking
A password must comply with the following
requirements:
requirements:
It cannot contain username or reversed username.
It cannot contain any of the following strings: cisco,
sciatl, ocsic, Itaics, atlsci, icslta,or any string
achieved by full or partial capitalization of letters.
achieved by full or partial capitalization of letters.
No letter is repeated more than three times in a row.
Must contain a minimum of eight characters.
Must contain a minimum of three of the following
types of characters: capital letters, small letters,
digits, and special characters.
digits, and special characters.
Note: The complexity level changes will only affect the new user accounts and
password changes. It will not affect existing passwords. Any changes take effect
password changes. It will not affect existing passwords. Any changes take effect
immediately, and do not require the use of the Apply button.
To change your login password:
Note: You are allowed to only modify your own password.
Note: You are allowed to only modify your own password.
3 The Change Password for User field displays the password for the current login.
4 In the Enter Current Password field, type the current login password.
5 In the Enter New Password field, type the new login password.
6 In the Re-enter New Password field, type the new login password again to
4 In the Enter Current Password field, type the current login password.
5 In the Enter New Password field, type the new login password.
6 In the Re-enter New Password field, type the new login password again to
confirm. Once the password change is successful, the user will be directed to the
login screen to re-enter their username and password.
Note: The Enter New Password and Re-enter New Password should be
identical. Each user, including the admin user, can only modify their own
password.
login screen to re-enter their username and password.
Note: The Enter New Password and Re-enter New Password should be
identical. Each user, including the admin user, can only modify their own
password.
7 Click Apply.