Chapter 1    Introducing the Taps and Passives 
 
 
 
 
CAUTION: 
It is recommended that all unused F-ports be properly terminated with a 75 
terminator 
Connector Protection 
It is recommended that each feeder-line connector be properly protected against 
corrosion. This is accomplished by any sealing material such as heat-shrink, 
cold-shrink, or a suitable sealing tape. 
For taps, each F-port for drop connection is shipped with a protective plastic cap. 
Remove these plastic caps after the tap is installed. All drop connections should be 
protected against corrosion. This is accomplished by the use of appropriate sealing 
material such as heat-shrink or connector boots. It is also recommended that silicon 
grease be lightly applied to the threading of the drop connection. 
Connection Beam 
Our family of taps also consists of the Surge-Gap Stretch Tap. These taps include a 
connection beam AC/RF bypass switch that enables uninterrupted downstream 
signal flow when the tap faceplate is removed. These units are identifiable by a blue 
dot on the back of the housing. The end-of-line Surge-Gap Taps should be installed 
with power-blocking, 75 Ω terminators on the downstream output port. 
Taps and Passives Dimensions 
The following table contains the physical dimensions for the tap and passive. 
Item 
Length 
Width 
Depth 
2- and 4-port tap  3.6 in. (91.44 mm) 
3.6 in. (91.44 mm) 
3 in. (76.2 mm) 
8-port tap 
4.25 in. (107.95 mm)  5.5 in. (139.75 mm)  3 in. (76.2 mm) 
Passive 
4.5 in. (114.3 mm) 
5.5 in. (139.75 mm)  3 in. (76.2 mm) 
Pedestal Size 
The following table contains the recommended minimum pedestal size for various 
tap/passive configurations. 
Pedestal Size 
Splice Configuration 
4-in. by 4-in. 
• 
2-port tap 
• 
4-port tap 
 
OL-31976-01