Cisco Cisco Surge-Gap Passives Installation Guide

Page of 52
Appendix A  Technical Information 
     
 
 
 
 
Specifications 
The following are the specifications for the tap/passive system. 
Notes: 
 
Specifications are subject to change without notice. 
 
Please refer to product data sheets for RF performance specifications. 
 
 
Electrical 
The table below lists the electrical specifications for the 2/4-way and 2-/4-/8-way 
Surge-Gap Tap Systems. 
Item 
Specification 
Operational frequency bandwidth 
5 MHz to 1250 MHz 
Thru current rating 
12 A, 60/90 V AC 
Impedance 
75 Ω 
Interface 
F-ports 
Operating temperatures 
-40°F to +140°F (-40°C to +60°C) 
 
The table below lists the electrical specifications for the Surge-Gap Passive Systems. 
Includes DC- 8dB, DC-12dB, DC-16dB, 2 Way Splitter, 3 Way Splitter, 3 Way 
Unbalanced Splitter, and Power Inserter 
 
Item 
Specification 
Operational frequency bandwidth 
5 MHz to 1250 MHz 
Thru current rating 
15 Amps Max on RF ports, 20 A Max on Power 
Inserter AC port, 60/90 V AC 
Impedance 
75 Ω 
Interface 
F-ports 
Operating temperatures 
-40°F to +140°F (-40°C to +60°C) 
 
 
 
Mechanical 
The table below lists the mechanical specifications for all the Surge-Gap Taps and 
Passives. 
 
32 