1.  Check for LED status on the interface ports 
2.  When the Streamer starts its POST procedure, enter the system BIOS setup by 
pressing <DELETE> within the first 10 seconds and while the “enter BIOS” option is 
displayed on the screen. When in the BIOS confirm the following elements below, 
save the BIOS settings and reboot. 
 
Advanced -> Console Redirection: 
 
Console Type is set to VT100, 8 bit 
 
Baud rate is set to 9600 
 
Flow Control is set to XON/XOFF 
 
Default Values: 
 
Advanced -> Advanced Chipset Control -> SERR Signal Condition: is set to 
Uncorrectable” 
 
Advanced -> Advance Chipset Control -> Max Payload Size: 128B 
 
 
3.  After rebooting, check the firmware version of the SAS controller. This will appear 
after the BIOS and first LSI adapter POST screens. Figure 19 above is the 
screen shot to refer. 
 
4.  The 
“FW package:” string should be displayed as 12.12.0-0090. If it is not 
12.12.0-0090, reboot the box and follow the BIOS upgrade procedure in 
Appendix A. 
 
5.  Perform a file system health check prior to the card replacement. This step is to 
be performed in single user mode.  
 
a.  Bootup the server 
b.  During bootup, when list of Linux versions appears, select CDS TV Linux 
version and hit 'e' for edit. 
 
c.  hit 'e' again on 2nd line as shown below: