Cisco Cisco Content Delivery Engine 220 Technical References

Page of 59
MegaRAID SAS Controller Replacement Procedure 
OL-27138-01 
 
 
 
All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
 
32 
 
[/sbin/fsck.ext3 (2) -- /boot] fsck.ext3 -a /dev/hda1 
/boot: clean, 52/64256 files, 45271/257008 blocks 
/var1: clean, 182/2560864 files, 122093/2560359 blocks 
[/sbin/fsck.ext3 (1) -- /home] fsck.ext3 -a /dev/sda2 
/home1: clean, 380/7685440 files, 336081/7679070 blocks 
[/sbin/fsck.ext3 (1) -- /arroyo] fsck.ext3 -a /dev/sda6 
/arroyo1: clean, 1219/217808896 files, 8531636/217785164 blocks 
[/sbin/fsck.ext3 (1) -- /arroyo/db] fsck.ext3 -a /dev/sda1 
/arroyo/db: clean, 359/12812288 files, 470311/12799780 blocks 
 [  OK  ] 
Remounting root filesystem in read-write mode:  [  OK  ] 
Mounting local filesystems:  [  OK ] 
 
h.  Reboot the server at the single 
mode prompt ‘sh-3.1’ by running the command:
 
sh-3.1# shutdown -rF now 
 
6.  After the file system check is complete and clean, reboot and verify that the Streamer 
shows up Green in the CDSM/VVIM and remove the offload status at the following menu: 
 
 
 
 
 
Maintain/Server/Server Offload Online/Disable 
7. 
On site engineer login using username “root”, password “rootroot”. Use ” 
/home/stats/ifstats” command to see if there are any errors 
Example: 
 
 ifstat: Thu Oct 28 05:33:01 2010 
============================================================ 
Int    R-Mbps    X-Mbps    R-Bytes        X-Bytes 
eth0:    0.58    0.39    1088543703    862586838 
eth1:    0.00    0.00    20100765118    396150330 
eth2:    22.36    178.26    76769268012    302026793912 
eth3:    0.00
    173.48    4814784    303403606668 
eth4:    21.66    172.64    76761475384    302042111800 
eth5:    22.29    178.29    76747790924    302079733868 
eth6:    0.00
    179.09    4821376    302082805164 
eth7:    22.42    179.00    76777223880    302028469464 
eth8:    21.59    173.11    76767383634    302081217352 
eth9:    22.37    178.85    76766286360    302091012368
 
 
8.  Check protocoltiming logs for transmission errors  
 
9.  Proceed to Step 1 to start the next Caching Gateway
 
Detailed Procedure for Persistent Stores 
Pre-Upgrade Procedure for Content Libraries 
 
1.  Start first with the non-master Persistent Stores in the cluster. 
 
2.  Make sure there are no active ingests before upgrading This can be done by offloading 
the device in the manager prior to the upgrade,