Cisco Cisco Content Delivery Engine 220 Technical References

Page of 59
MegaRAID SAS Controller Replacement Procedure 
OL-27138-01 
 
 
 
All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
 
44 
 
[/sbin/fsck.ext3 (1) -- /var] fsck.ext3 -a /dev/sda3 
[/sbin/fsck.ext3 (2) -- /boot] fsck.ext3 -a /dev/hda1 
/boot: clean, 52/64256 files, 45271/257008 blocks 
/var1: clean, 182/2560864 files, 122093/2560359 blocks 
[/sbin/fsck.ext3 (1) -- /home] fsck.ext3 -a /dev/sda2 
/home1: clean, 380/7685440 files, 336081/7679070 blocks 
[/sbin/fsck.ext3 (1) -- /arroyo] fsck.ext3 -a /dev/sda6 
/arroyo1: clean, 1219/217808896 files, 8531636/217785164 blocks 
[/sbin/fsck.ext3 (1) -- /arroyo/db] fsck.ext3 -a /dev/sda1 
/arroyo/db: clean, 359/12812288 files, 470311/12799780 blocks 
 [  OK  ] 
Remounting root filesystem in read-write mode:  [  OK  ] 
Mounting local filesystems:  [  OK ] 
 
h.  Reboot the server at the single 
mode prompt ‘sh-3.1’ by running the command:
 
sh-3.1# shutdown -rF now 
 
6.  After the file system check is complete and clean, reboot and verify that the persistent 
store shows up Green in the VVIM and remove the offload status:
 
 
Maintain/Server/Server Offload Online/Disable 
 
 
7. 
On site engineer login using username “root”, password “rootroot”. Use ” 
/home/stats/ifstats” command to see if there are any errors 
Example 
 
ifstat: Thu Oct 28 05:33:01 2010 
============================================================ 
Int    R-Mbps    X-Mbps    R-Bytes        X-Bytes 
eth0:    0.58    0.39    1088543703    862586838 
eth1:    0.00    0.00    20100765118    396150330 
eth2:    22.36    178.26    76769268012    302026793912 
eth3:    0.00
    173.48    4814784    303403606668 
eth4:    21.66    172.64    76761475384    302042111800 
eth5:    22.29    178.29    76747790924    302079733868 
eth6:    0.00
    179.09    4821376    302082805164 
eth7:    22.42    179.00    76777223880    302028469464 
eth8:    21.59    173.11    76767383634    302081217352 
eth9:    22.37    178.85    76766286360    302091012368
 
 
8.  Check protocoltiming logs for transmission errors  
 
9.  Proceed to the next Content Library
Replacing the Old SAS card: 
 
The basic steps to replace back the Old SAS card: 
1.  Offload the server 
2.  Stop database 
3.  Power off the server, remove the Power cords and remove the Power supplies 
4.  Open the server chassis and replace back the old MegaRAID card 
5.  Boot up the server