Cisco Cisco Content Delivery Engine 220 Technical References

Page of 59
MegaRAID SAS Controller Replacement Procedure 
OL-27138-01 
 
 
 
All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
 
 
power supplies and disconnect all the cables on the rear panel for physically replacing 
the MegaRAID controller. 
5.  Open the chassis to replace the old MegaRAID controller with the new one. 
6.  Import logical drive configuration from the physical drives to the new card, if prompted to 
do so. 
7.  Upgrade the firmware for the new MegaRAID controller by using the DOS bootable USB 
key with the new firmware.  
8.  Pull out the USB key and reboot the server after the firmware upgrade is done. 
 
See the section below for the details of each step: 
Detailed Procedure for Streamers: 
Pre-Upgrade Procedure for Streamers: 
 
 
1.  Start first with the secondary Streamers in the cluster followed by the primary streamer. 
 
2.  Make sure there are no active streams before upgrading. This can be done by off lining 
the device in the manager prior to the upgrade.  The offload command automatically 
pushes active streams to other streamer servers in the cluster and is not an end-user 
impacting operation. 
 
In the CDSM, select Maintain/Server/Server Offload Enable 
 
3.  Perform a file system health check prior to the card replacement. This step is to be 
performed in single user mode.  
a.  Bootup the server 
 
b.  During bootup, when list of Linux versions appears on the screen, select CDS-TV 
Linux version and hit 'e' for edit  
 
c.  hit 'e' again on 2nd line as shown below 
 
 
Figure 8: GRUB