Cisco Cisco Content Delivery Engine 220 Installation Guide

Page of 13
MegaRAID SAS Controller BBU Replacement Procedure 
EDCS-1458166 
 
 
 
All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
 
11 
 
High-Level Summary of the Replacement Steps: 
1.  Take the server offline  from CDSM. 
2.  Issue the “init 0” command from the console. 
3.  Disconnect the power  cords from  the power  supplies, remove  the power  supplies and 
disconnect all the cables on the rear panel  for  physically replacing  the  9261-8i  MegaRAID 
controller. 
4.  Open the chassis and remove  the 9261-8i  MegaRAID controller. 
5.  Remove  the BBU from the 9261-8i  MegaRAID controller. 
6.  Install the new BBU on the 9261-8i  MegaRAID controller. 
7.  Replace  the 9261-8i  MegaRAID controller  in the chassis. 
8.  Replace  the SAS cables  to the  9261-8i  MegaRAID  controller, replace the power  supplies, 
and the power  cords 
9.  Reboot  the server. 
 
See the section below for the details of each step: 
Procedure for removing the 9261-8i MegaRAID controller and 
replacing the BBU: 
 
 
1.  In the CDSM, select Maintain/Server/Server  Offload  Enable 
 
2.  SSH as root to the device  that is targeted  for an upgrade.  Stop database  by issuing the 
following commands: 
a.  as root, issue "
db_shutdown
b.  make sure avsdb process shuts down, "
pgrep avsdb
"  and “
netstat –an |grep 
9999
” should return nothing 
c.  issue the “init 0” command 
 
3.  Inspect the server  chassis and ensure all connecting cables are labeled, if fibers are in 
use for streaming, ensure  that TX/RX  are  marked by color or label.  If any cables/fibers 
are missing label, use temporary label to show near end interface
.
 
4.  Power off the server,  disconnect the power cords from the power supplies, remove  the 
power supplies  and disconnect all the cables on the rear panel. 
5.  Place the chassis on a workstation and remove  the top cover; 
 
Note: Make sure you have an ESD strap on and you are properly grounded  before 
proceeding. 
 
6.  Unscrew  the bracket of the 9261-8i MegaRAID controller card  at slot 3 on the 
CDE220/420, slot 1 on the CDE250/460/470. 
7.  Disconnect the mini SAS cable attached to the 9261-8i MegaRAID controller. 
8.  Remove 9261-8i  MegaRAID  controller from the chassis.