Cisco Cisco Digital Service Access Node (DSAN) 8210 Installation Guide
Chapter 5 SNMP Management
128
78-4041038-01 Rev B
The default value is disable(1).
Access: Read-write
Syntax: Integer
OID: 1.3.6.1.4.1.1429.1.10.2.1.2.10.5
saDsanAdminUcCraft
This object enables or disables the ability to use the craft interface on the unit. Reboot
or eHostReset is required for changes to take effect. Verify status via
saDsanAdminUserConfigStatus.
or eHostReset is required for changes to take effect. Verify status via
saDsanAdminUserConfigStatus.
Valid values are:
disable (1)
enable (2)
The default value is enable(2) to allow a serial connection to the unit.
Access: Read-write
Syntax: Integer
OID: 1.3.6.1.4.1.1429.1.10.2.1.2.10.6
User Config Aux Table
Use the objects in the User Config Aux table to provision the Auxiliary inputs with
output EIA channels.
output EIA channels.
saDsanAdminUcAuxEntry
Row of table, indexed by the entry number.
Access: N/A
Syntex: Integer
OID: 1.3.6.1.4.1.1429.1.10.2.1.2.10.7.1
saDsanAdminUcAuxIndex
Index used for displaying the table.
Access: N/A
Syntax: Integer
OID: 1.3.6.1.4.1.1429.1.10.2.1.2.10.7.1.1
saDsanAdminUcAuxInput
This object shows the input number of the configured auxiliary port.