Chapter 3    Hardware Installation 
 
 
 
48 
78-4041038-01 Rev B 
 
 
 
5  Position the housing on the wall or in the rack. 
6  Secure the mounting bracket to the wall or rack as follows: 
 
For wall mounting, use four 5/16-inch lag bolts of sufficient length to allow a 
minimum 2-inch thread engagement with the studs. Torque the mounting 
bolts from 8 to 10 ft-lb (10.8 to 13.6 Nm). 
 
For rack mounting, use eight #10 x 32 machine screws and compatible nuts. 
The screws should be long enough to extend at least two threads beyond the 
outer face of the nut. Torque the screws from 25 to 30 in-lb (2.8 to 3.4 Nm). 
7  Connect the coaxial cable to the pin connector according to connector 
manufacturer specifications. 
Proceed to Installing Accessories (on page 50). 
 
To Install the Housing on a Strand or in a Cabinet 
Complete the following steps to install the DSAN unit on a strand or in a cabinet or 
pedestal enclosure. 
Note: The housing does not need to be opened for strand, cabinet, or pedestal 
installation. 
Important: The minimum strand diameter should be 5/16 inch. 
 
CAUTION: 
Be aware of the size and weight of the node while strand mounting. 
Ensure that the strand can safely support the weight of the node.