Cisco Cisco Digital Service Access Node (DSAN) 8210 Installation Guide
Chapter 5 SNMP Management
118
OL-30954-01
Manufacturing Group
The Manufacturing group contains elements for reading the manufacturing serial
number, model number, date code, time of service (TOS, or number of hours in
operation), Secure Micro information, and DSAN board revision numbers.
number, model number, date code, time of service (TOS, or number of hours in
operation), Secure Micro information, and DSAN board revision numbers.
saDsanMfgSerialNumber
The value in this object represents the manufacturing serial number of the unit.
Access: Read-only
Syntax: DisplayString
OID: 1.3.6.1.4.1.1429.1.10.2.1.1.1
saDsanMfgModel
The value in this object represents the model number of the unit.
Note: The model number for this product is 8210.
Access: Read-only
Syntax: DisplayString
OID: 1.3.6.1.4.1.1429.1.10.2.1.1.2
saDsanMfgDateCode
This object holds a string of three characters representing the manufacturing date of
the unit. A letter specifying the month is followed by two digits indicating the year
that the unit was built and tested.
the unit. A letter specifying the month is followed by two digits indicating the year
that the unit was built and tested.
The following letters are used to specify the month:
Letter
Month
A
January
B
February
C
March
D
April
E
May
F
June
G
July
H
August
J
September
K
October