Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Data Sheet

Page of 10
GainMaker Node – 5-40/52-1002 MHz with RF Redundancy 
 
8
 
 
Specifications, continued 
 
Electrical 
Units 
 
Notes 
Max. AC Through Current (continuous) 
Amps 
15 
 
Max. AC Through Current (surge) 
Amps 
25 
 
Component DC Power Consumption (typical) 
 
@ +24 VDC 
@ +15 VDC 
@ -6 VDC 
Launch Amplifier HGBT (thermal) 
Amps 1.51 
 
Standard Optical Receiver Amps 
0.25 
0.01 
0.035 
 
Reverse Transmitter – Standard FP 
Amps 
0.14 
0.07 
 
Reverse Transmitter – Standard DFB 
Amps 
0.14 
0.09 
 
 
 
 
 
 
 
Power Supply DC Current Rating 
Amps 
3.0 
0.05 
0.3 
 
Station Powering Data 
AC Voltage 
 
GainMaker HGBT 
Node 
DC 
(Amps at 
24 V DC)
 
 
90 
85 
80 
75 
70 
65 
60 
55 
50 
45 
40 
AC 
Current 
(A)  0.98 1.02 1.01 1.05 1.09 1.16 1.32 1.41 1.54 1.71 1.93 
1 RX, 1 TX, 
& Stat Mon 
2.5 
Power 
(W) 
70.8 70.7 70.5 70.4 70.2 70.2 70.4 70.4 70.4 70.6 70.8 
 
Data is based on stations configured for 2-way operation with status monitoring transponder.  AC currents specified are based on 
measurements made with typical CATV type ferro-resonant AC power supply (quasi-square wave), and standard version DC power 
supply. 
 
DC supply has a user configurable 40 V or 50 V AC under-voltage lockout circuit. 
 
 
Note: 
1. 
The total DC Power consumption of installed components should not exceed the power supply DC current rating. 
 
 
Environmental 
Units 
 
Operating Temperature Range 
degrees 
-40
°F to 140°F (-40°C to 60°C) 
Relative Humidity Range 
percent 
5% to 95% 
Mechanical  
 
 
Housing Dimensions 
Weight 
Station with 1 RX, 1 TX, & power supply:   22 lbs (9.9 kg) 
17.5 in. L x 7.3 in. H x 7.5 in. D  
(445 mm L x 185 mm H x 191 mm D) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Unless otherwise noted, specifications reflect typical performance and are referenced to 68
°F (20°C).  Specifications are based 
upon measurements made in accordance with SCTE/ANSI standards (where applicable), using standard frequency assignments.