Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 180
Chapter 4    Troubleshooting 
 
 
 
 
 
No AC Power Troubleshooting Table 
Before you begin troubleshooting for no AC power, verify that there is proper AC 
power input coming into the node. 
Possible cause 
Solution 
No AC at the AC test point on the 
AC/RF entry module. 
 
Check the AC source. 
 
Check the AC shunt power director 
configuration at the amplifier feeding AC to 
this amplifier. 
AC at the AC test point but not the 
AC shunt power director. 
 
Check and/or replace the AC shunt power 
director. 
 
Check and/or replace the amplifier module. 
AC at the AC test point but not the 
power supply test point. 
 
Check and/or replace the power supply wiring 
harness. 
 
Check and/or replace the power supply. 
 
 
 
86 