Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 180
Chapter 4    Troubleshooting 
 
 
 
Low or Degraded Reverse RF Signal 
The reverse RF signal can be measured at the amplifier module reverse input test 
point and the reverse optical transmitter output test point. 
 
Low or Degraded Reverse RF Signal Troubleshooting Table 
Before you begin troubleshooting for no reverse RF signal, verify that the amplifier is 
receiving the proper reverse RF input signals from the downstream amplifiers. 
Important:  You cannot balance the amplifier without the proper reverse RF input 
signals. 
Make sure you have configured the amplifier module according to the specifications 
in the design print, and that the amplifier has warmed up for approximately one 
hour. 
Make sure you are using the proper total tilt reference when setting receive levels. 
Important:  If the amplifier cover was ever removed, make sure it was properly 
reinstalled. Improperly reinstalling the amplifier module cover may result in RF 
signal degradation. 
Possible cause 
Solution 
Low or degraded reverse RF signal 
at the reverse input test point(s). 
 
Verify that the amplifier is receiving the proper 
reverse RF input signals from the downstream 
amplifiers. 
Important: You cannot balance the amplifier 
without the proper reverse RF input signals. 
There are proper reverse RF signals 
at the reverse input test points, but a 
low or degraded signal at the reverse 
transmitter output test point. 
 
Verify that the amplifier module is receiving 
the proper DC voltages. Refer to No DC Power 
(on page 87). 
 
Verify that all the proper accessories, pads, 
EQs, and signal directors (if applicable) are 
firmly installed in the correct locations. 
 
Verify that the factory installed accessories are 
firmly installed in the correct locations. 
 
Verify that the reverse switch and its jumpers 
are properly and firmly installed. 
 
Check/replace the wiring harness. 
Note: Verifying factory installations involves 
removing the amplifier module cover. Reinstall 
the amplifier module cover properly or RF 
signal degradation may result. 
 
94 