Reverse Balancing the Node with the Enhanced Digital Return (EDR) Modules 
 
1  Refer to the reverse system design print on the RF amplifier assembly cover and 
inject the proper level into the reverse injection (forward output) test point of a 
port of the RF launch amplifier with a reverse sweep transmitter or a CW signal 
generator. The insertion loss of all forward output test points is 20 dB (relative to 
corresponding port). 
Note:  For the location of the reverse injection test point of each port, see 
Illustrations. 
Important:  To calculate the correct signal level to inject, add the reverse input 
level (from the design print) to the insertion loss of the reverse injection test 
point. 
Formula: 
Reverse input + Insertion loss = Signal generator setting 
Example: 
Reverse input = 15 dBmV 
Insertion loss = 20 dBmV 
Result:  Signal generator setting=15 dBmV + 20 dB = 35 dBmV 
Note: The ADC full-scale (100%) level for a single CW carrier is +33 dBmV. This 
is the level at which the ADC begins clipping. 
Note:  The reverse attenuator (pad) and reverse equalizer in the 1 GHz 
GainMaker Node is selected during the reverse system design, and it is based on 
the drive level into the digital module which is determined by system 
performance requirements, type and quantity of return carriers, etc. Consult data 
sheet to determine proper operational level. 
2  Verify the level of the reverse output test point. This output level leaves the RF 
launch amplifier via the coaxial cable to the multiplexing digital module input. 
(Use an SMB connector to F-connector test cable.) 
3  Have the person in the headend refer to the headend system design and set the 
output of the EDR receiver to the specified output level. See the instruction guide 
that was shipped with EDR receiver for setup procedures. 
 
 
OL-30326-02 