Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 180
 
 
EDR Digital Return Multiplexing Applications 
Follow the steps in the table below to troubleshoot the transmitter module. 
Symptom 
Possible Cause 
Possible Solutions 
No optical signal output 
Laser temperature could be 
too high or low. 
Allow up to one minute after 
power is ON for the 
temperature to stabilize. 
If still no output, contact the 
Technical Service Center for 
assistance. 
Laser could be faulty. 
Contact the Technical Service 
Center for assistance. 
Automatic power control 
circuit failure. 
Contact the Technical Service 
Center for assistance. 
 
Damaged fiber. 
Contact the Technical Service 
Center for assistance. 
 
Symptom 
Possible Cause 
Possible Solutions 
No optical signal output 
(cont'd) 
One or more power supply 
voltages are out of 
specification. 
Check the power supply for 
proper operation. 
No AC at receptacle. 
Check the receptacle for AC 
power. 
Blown fuse on the power 
supply. 
Check the power supply fuse 
and replace as necessary. 
 
Faulty module. 
Contact the Technical Service 
Center for assistance. 
 
 
 
 
 
 
 
 
146 
OL-30326-02