Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 180
Chapter 1    Introduction 
 
 
 
Power Supply 
The DC power supply has the following features. 
 
Located in housing lid for ease of maintenance 
 
AC and DC test points provided on both the power supply and the amplifier 
board 
 
Selectable AC undervoltage lockout feature 
-
 
The 40 volt lockout is for 60/90 volt systems (factory default) 
-
 
The 50 volt lockout position can be selected for operation in 90 volt systems 
(field configurable by moving a jumper) 
 
Input and Output Ports 
This amplifier has one optical input port and two or three RF output ports. The 
number of output ports is determined by which one of the following is installed in 
the plug-in signal director position: 
 
Jumper 
 
2-way splitter 
 
8 dB directional coupler 
 
12 dB directional coupler 
Note: Either the Aux1 or Aux2 output port could be selected and the second output 
port with the jumper accessory installed. The 2-way splitter, 8 dB coupler, and 12 dB 
coupler activate both Aux1 and Aux2 ports. 
Configuration 
All GainMaker Node amplifier modules are configured with the following. 
 
Diplex Filters 
 
Reverse Amplifier 
 
Forward Interstage Equalizer (Linear)   
 
Forward Interstage and Output Attenuator Pads 
 
RF Interface Board 
 
Test Points 
There are seven RF and four voltage test points on the node. 
 
AC Shunt Power Directors 
The node amplifier module  has four AC shunt power directors located near the 
 
OL-30326-02