Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide
Before You Begin
Fastener
Torque Specification
Illustration
Pedestal mounting bolts
8 ft-lb to 10 ft-lb
(10.8 Nm to 13.6 Nm)
75 ohm terminator
Per manufacturer instructions
(Appearance
varies by
manufacturer)
System amplifier module
shoulder screws (slotted head)
6 in-lb to 9 in-lb
(0.7 Nm to 1.0 Nm)
System amplifier module
shoulder screws (cross head)
18 in-lb to 20 in-lb
(2.0 Nm to 2.25 Nm)
Housing closure bolts
5 ft-lb to 12 ft-lb
(6.8 Nm to 16.3 Nm)
Housing plugs
Test point port plugs
5 ft-lb to 8 ft-lb
(6.8 Nm to 10.8 Nm)
Module securing screws
(Tx, Rx, PS, SM/LCM modules)
(Tx, Rx, PS, SM/LCM modules)
25 in-lb to 30 in-lb
(2.8 Nm to 3.4 Nm)
RF cable connector
Per manufacturer instructions
Fiber optic cable connector
20 ft-lb to 25 ft-lb
(27.1 Nm to 33.9 Nm)
Weight Specifications
Before strand (aerial) mounting or pedestal mounting the node, follow the
precautions below.
WARNING:
The node weighs approximately 39 lbs (18 kg). To avoid personal injury and damage to
The node weighs approximately 39 lbs (18 kg). To avoid personal injury and damage to
the equipment, perform the following:
Ensure that the strand or pedestal can support the weight of the node.
Use safe handling and lifting practices in accordance with your
organization’s procedures.
Housing Dimensions
This illustration shows the dimensions, in inches and millimeters, of the node
housing with a standard lid. Use these measurements to calculate clearance
requirements for your installation.
OL-30326-02