Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 180
 
Preparing for Forward Path Balancing 
corporate engineering policy. 
Switch S1 Position Information for Thermal Configured Stations 
Position 1 
Amplifier Only 
Position 2 
NOT USED 
Position 3 
Amplifier and Coax 
NOT USED 
A thermistor (thermal) driven 
circuit on the amplifier sets the 
DC control voltage that drives 
the Bode. 
This circuit detects the 
amplifier’s internal temperature 
and generates the proper level 
of DC control voltage, setting 
the proper loss characteristics of 
the Bode with respect to the 
current outdoor temperature. 
Note:
 This switch position is 
meant to compensate for the 
temperature related level 
variations of the amplifier only.   
This switch position is normally 
selected when underground 
cable precedes the station, since 
such cable is subject to little 
temperature variation. 
Important: Do not select this 
position. This position is reserved 
for stations with an AGC 
installed. 
While adjustments to the Manual 
Backoff potentiometer will affect 
amplifier gain with S1 in this 
position, once S1 is set to position 
1 or 3, the manual potentiometer 
setting will not affect proper 
thermal amplifier operation. 
Leaving the switch in this position 
disables the thermistor (thermal) 
driven circuit and enables the 
backoff potentiometer on the 
amplifier.    This sets the DC 
control voltage that drives the 
Bode to a constant setting, 
regardless of the current outdoor 
temperature. 
Note: This is a factory setting used 
to verify proper station gain with 
a given amount of manual gain 
backoff. 
Note: This switch position is 
meant to compensate for the 
temperature related level 
variations of both the amplifier 
and the coaxial cable preceding 
the station. 
This switch position is normally 
selected when overhead cable 
precedes the station, since such 
cable is subject to temperature 
variation. 
Therefore, this switch position is 
not recommended for use with 
nodes. 
Note: Switch S1 in Position 2, and the backoff potentiometer, are used in AGC stations only. 
 
To Verify the Input Signal Level 
Complete the following steps to test the input signal level from the optical receiver. 
Important: You cannot balance the amplifier without the proper input signals. 
1  Connect the test equipment to the output test point on the receiver as shown in 
the following illustration. 
Important: The receiver output test point performs as the input test point for the 
amplifier. 
 
2  Measure the signal level at the following frequencies: 
 
The lowest frequency specified in the system design 
 
OL-30326-02 
51