Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 180
Chapter 3    Balancing and Setup 
 
 
 
Important: The forward input equalizer is installed at the factory and should not 
be changed in the field. While it is a 1 GHz equalizer, it is appropriate for use in 
both 1 GHz and 870 MHz applications. 
3  Measure the output tilt again, and then return to step 1. 
 
 
To Set the Output Level 
After setting the tilt, complete the following steps to select the proper pad values for 
the amplifier. The output level of the amplifier is set by selecting the proper pad 
value. 
1  Connect the test probe to the forward main output test point. 
2  Measure the output level at the highest design frequency, and compare this level 
with the design level (on the design print). 
3  Is the measured output level within ±0.5 dB of the design level? 
 
If the output level is within ±0.5 dB of the design output level, proceed to 
step 5. 
 
If the output level is more than the design output level, replace the forward 
input pad with a higher value pad. 
 
If the output level is less than the design level, replace the forward input pad 
with a lower value pad. 
4  Repeat steps 2 and 3 until the output level is correct. 
Note:  On the High Gain Dual, the type of plug-in signal director installed 
directly affects the signal level measured at the Aux RF output test points. This is 
because the Aux RF output test points are located after the signal director in the 
forward RF signal path instead of before  as in previous versions of system 
amplifiers (II, II+, and III). The test points now reflect the actual output of the 
port. 
It is important to determine if the Aux output level specified on the design print 
is the level before or after the signal director. 
 
If it is the level after  the signal director (port output level), the test point 
should match the print design level. 
 
If it is the level before the signal director, the test point level should be “x” dB 
lower than the print design level, where “x” is the insertion loss of the signal 
director feeding the particular Aux port being balanced. 
5  Proceed to To Set Up Automatic Gain Control
 
To Set Up Automatic Gain Control 
This section provides procedures and tables for configuring and aligning the AGC in 
the GainMaker node. AGC attenuator values are required to select the proper AGC 
attenuator value based upon actual AGC pilot carrier output level. See To Select the 
AGC Pad Value
Note: 
 
58 
OL-30326-02