Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 174
 
 
Opening and Closing the Node Housing 
 
Opening and Closing the Node Housing 
To Close the Node Housing 
Complete the following steps to close the node housing. 
 
CAUTION: 
Avoid moisture damage and RF leakage! Follow the procedure exactly 
as shown below to ensure a proper seal. 
1  Make sure that the housing gaskets are clean and in the correct position. Wipe off 
any excess dirt and debris. 
2  Close the housing. 
 
CAUTION: 
Ensure that all the cables are out of the way when closing the housing. 
3  Lightly secure the six ½-inch closure bolts with a hex driver or ratchet. 
4  Using a torque wrench, tighten the six closure bolts to 25 in-lb (2.8 Nm). 
Important: Tighten the closure bolts in the correct sequence as specified in 
Torquing Sequence (on page 16). 
5  Using the same pattern, tighten the housing closure bolts from 5 ft-lb to 12 ft-lb 
(6.8 Nm to 16.3 Nm). 
 
To Open the Node Housing 
Complete the following steps to open the node housing. 
Important: Before unscrewing the housing bolts, make sure the removable locking 
screw in the hinge is in place and secure. The locking screw prevents separation of 
the lid from the base. 
1  Unscrew the ½-inch housing closure bolts on the housing lid until they are loose. 
 
2  Open the housing. 
 
OL-29644-03 