Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 174
Chapter 4    Troubleshooting 
 
 
 
Cleaning Optical Connectors 
Optical Connector Cleaning Overview 
Cleaning fiber-optic connectors can help prevent interconnect problems and 
therefore aid system performance. When optical connectors are disconnected and 
reconnected, the fiber surface can become dirty or scratched. The goal of cleaning the 
fiber optic connectors is to remove all dust and contaminants without leaving any 
residue. 
 
Recommended Equipment 
The following equipment is recommended to clean the ends of fiber-optic 
connectors. 
 
CLETOP or OPTIPOP ferrule cleaner (CLETOP Type A for SC, Type B for LC) 
 
Compressed air (also called “canned air”) 
 
Lint-free wipes moistened with optical-grade (99%) isopropyl alcohol 
 
Bulkhead swabs for LC or SC type connectors (choose appropriate type) 
 
Optical connector scope 
 
Tips for Optimal Fiber-Optic Connector Performance 
Follow these guidelines to ensure optimal connector performance. 
 
Do not connect or disconnect optical connectors while optical power is present. 
 
Always use compressed air before cleaning the fiber-optic connectors. 
 
Always use end caps on connectors when they are not in use. 
 
Always use compressed air to clean the end caps. 
 
If you have any degraded signal problems, clean the fiber-optic connector. 
 
Advance a clean portion of the ferrule cleaner reel for each cleaning. 
 
Turn off optical power before making or breaking optical connections in order to 
avoid microscopic damage to fiber mating surfaces. 
 
 
 
78 