No Reverse RF Signal 
No Reverse RF Signal 
The reverse RF signal can be measured at the amplifier module reverse input test 
point and the reverse optical transmitter output test point. 
 
No Reverse RF Signal Troubleshooting Table 
Before you begin troubleshooting for no reverse RF signal, verify that the amplifier is 
receiving the proper reverse RF input signals from the downstream amplifiers. 
Important: You cannot balance the amplifier without the proper reverse RF input 
signals. 
Possible cause 
Solution 
No reverse RF signal at the reverse 
input test point(s). 
 
Verify that the amplifier is receiving the proper 
reverse RF input signals from the downstream 
amplifiers. 
Important: You cannot balance the amplifier 
without the proper reverse RF input signals. 
There are proper reverse RF signals 
at the reverse input test points, but 
no signal at the reverse transmitter 
output test point. 
 
Verify that the amplifier module is receiving 
the proper AC and DC voltages. Refer to No 
AC Power (on page 85) and No DC Power (on 
page 87). 
 
Verify that all the proper accessories, pads, and 
EQs are firmly installed in the correct locations. 
 
Verify that the factory installed accessories are 
firmly installed in the correct locations. 
 
Verify that the reverse switch (if applicable) or 
its jumpers are properly and firmly installed. 
Note: Verifying factory installations involves 
removing the amplifier module cover. Reinstall 
the amplifier module cover properly or RF 
signal degradation may result. 
 
Check/replace the wiring harness. 
 
Replace the amplifier module. 
 
 
 
OL-30035-03 
93