Cisco GainMaker Optoelectronic Node 1GHz with 55 70 MHz Split Installation Guide

Page of 10
4007941 Rev D 
 
 
 
Installing the Transponder 
 
LED 
Indication 
Heart Beat 
This green LED flashes approximately once per second if the 
transponder receives the correct voltage. 
Receive 
This green LED flashes if data packages are detected (e.g., to 
another transponder). If the data packages are addressed to this 
transponder, the LED flashes for 3 seconds. 
Error 
This red LED flashes during start-up. If this LED illuminates 
during operation, a system failure has occurred. 
 
Start/Restart Signaling 
Immediately after the transponder starts or restarts, all LEDs illuminate and remain 
on. Approximately 7 seconds later, the Receive and Error LEDs turn off and the 
Heart Beat LED begins flashing rapidly until the transponder locates an open 
communication frequency. When the transponder finds an open frequency, the 
Heart Beat LED slows to approximately one flash per second.