Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Technical References

Page of 6
 
 
 
1 GHz GainMaker System Amplifier 
Low Forward Band Roll-off Technical 
Bulletin 
Overview 
An issue was discovered recently with 1 GHz GainMaker® System Amplifiers 
exhibiting signal roll-off in the lower portion of the forward frequency band. The 
roll-off occurs when one or more capacitors in the pre-amplifier section become 
fractured. The effect of the damaged capacitor(s) on performance is most 
significant and noticeable in the lower portion (channels 2-6) of the forward band. 
Our experience has shown that units containing these fractured capacitors will fail 
within a few days of installation and power-up. If an amplifier exhibits the trouble 
symptom described in this document, we recommend returning the unit to Cisco 
for repair or replacement. Refer to For Information (on page 5)
Important! This phenomenon only occurs in GainMaker 1 GHz High Gain Dual 
(HGD) and High Gain Balanced Triple (HGBT) amplifiers and nodes, and in Low 
Gain Dual (LGD) amplifiers. 
Purpose 
This technical bulletin explains to customers using any of the above amplifiers or 
nodes how to identify units possibly affected by this issue, and how to initiate 
return of any affected units. 
Audience 
This document is intended for authorized service personnel who have experience 
working with similar equipment. The service personnel should have the 
background and knowledge required to understand and verify the information 
provided in this document. 
Qualified Personnel 
Only appropriately qualified and skilled service personnel should attempt to 
install, operate, maintain, and service this product.