Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Technical References
Closing the Housing,
Continued
3.
Use a torque wrench with a 1/2-in. socket to tighten each closure bolt from
5 ft-lb to 12 ft-lb (6.8 Nm to 16.3 Nm) each.
Note: Ensure that any test point plugs are tightened from 2 ft-lb to 4 ft-lb
(2.7 Nm to 5.4 Nm).
Important: Follow this numbered sequence to tighten the closure bolts.