Overview 
A small number of optical interface boards (OIB) in the Model GS7000 
GainMaker
®
 Scaleable 4-Port Nodes have experienced an electrical short.  The 5 V 
DC and 24 V DC power planes have shorted to each other and sometimes to 
ground.  These two voltages and the ground plane are on different layers of the 
six-layer OIB printed wiring board (PWB).  The short could affect performance of 
the forward or reverse path, or both.  It could even result in a node outage. 
Purpose 
The purpose of this technical bulletin is to provide customers using the Model 
GS7000 Node with information regarding: 
 
Identification of potentially affected nodes 
 
Condition symptoms and electrical verification for installed nodes 
 
Recommended customer action 
Audience 
This document is intended for authorized service personnel who have experience 
working with similar equipment. The service personnel should have appropriate 
background and knowledge to complete the procedures described in this 
document. 
Qualified Personnel 
Only appropriately qualified and skilled service personnel should attempt to 
install, operate, maintain, and service this product. 
 
  
WARNING: 
Allow only qualified and skilled personnel to install, operate, maintain, and 
service this product. Otherwise, personal injury or equipment damage may 
occur.