Chapter 4    Configuration and Testing 
 
 
 
58 
OL-29943-01 
Configuration and Testing Procedures 
The basic steps for configuring and testing the DSAN are as follows: 
 
Confirm the necessary headend software and server support 
 
Stage the DSAN hardware to meet installation requirements, verify signal levels, 
and make any adjustments needed 
 
Following installation, boot the DSAN and verify proper operation 
This section describes each of these steps in detail. 
 
Before You Begin 
Before you begin, confirm that you have set up the DSAN according to the 
specifications in your design print. 
The table below lists some items you may need to complete configuration. 
You need a ... 
To ... 
copy of the design print 
determine expected input and output signal 
levels. 
torque wrench with half-inch socket 
open and close the housing. 
spectrum analyzer or signal analysis 
meter capable of working with 
frequencies up to the highest design 
frequency 
determine input and output signal levels. 
test point adapter (part number 562580) 
or F-81 female-to-female adapter 
access the test points. 
length of 75 
 coaxial cable with F-
connectors on each end 
connect the test point adapter to the test 
equipment. 
voltmeter 
test the power supply AC and DC voltages. 
reverse sweep receiver 
test signals using a reverse sweep transmitter.