Cisco Model D-PCG1000 PowerKEY CAS Gateway User Guide
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
IPG Memory Usage Settings
OL-28804-01
65
Field Name
Description and Possible Values
Use Fixed Size
Grid File Data
Allocations KB
Grid File Data
Allocations KB
(0-variable)
This setting affects only the grid data, not the long descriptions. The
value entered in this field determines whether this setting is enabled
value entered in this field determines whether this setting is enabled
or disabled.
¡
Disabled - A zero in this field indicates that this setting is
disabled.
Note: Disabled is the default setting.
disabled.
Note: Disabled is the default setting.
¡
Enabled - When enabled, this field requires a value that is a
minimum of 10% larger than the largest grid data file on the
Application Server's disk.
Important: When using this setting, we recommend that each
week you verify the allocated size against the actual file sizes
and, if needed, increase the allocated file size.
Notes:
–
minimum of 10% larger than the largest grid data file on the
Application Server's disk.
Important: When using this setting, we recommend that each
week you verify the allocated size against the actual file sizes
and, if needed, increase the allocated file size.
Notes:
–
When using this setting, the Information bar indicates the
range of values allowed based on the size of the largest grid
data file, or displays that no grid data files have been found
when this is the case.
range of values allowed based on the size of the largest grid
data file, or displays that no grid data files have been found
when this is the case.
–
Entering a value in this field also causes a message to appear
to the right of the field that provides the minimum required
value.
to the right of the field that provides the minimum required
value.
–
This fixed size allocation applies only to the grid data for
days configured as "Never Purge."
days configured as "Never Purge."
–
When this value is changed, the Application Server will
attempt to resize the memory allocations for "Never Purge"
days when the new configuration data is received. However,
under tight memory conditions, the resizing may not occur
until much later (resizing is attempted periodically) and, if it
has not been able to resize the allocated memory to the newly
configured fixed size by midnight, when the days get
changed, the existing allocations might be deleted, and then
a new allocation to the proper size will be attempted.
attempt to resize the memory allocations for "Never Purge"
days when the new configuration data is received. However,
under tight memory conditions, the resizing may not occur
until much later (resizing is attempted periodically) and, if it
has not been able to resize the allocated memory to the newly
configured fixed size by midnight, when the days get
changed, the existing allocations might be deleted, and then
a new allocation to the proper size will be attempted.
The following IPG Memory Usage settings define when grid data for the current day
and next day will be purged.
and next day will be purged.
¾
Never Purge
¾
Automatic Priority-Based Purging
¾
Purge Only When Asked By Another App
Field Name
Default Setting
Current Day