16 
4035812 Rev B 
Confirming Normal Operation 
After installing the DAXI, confirm normal operation of the unit by checking the 
status of the front-panel LED indicators. 
 
 
PWR Indicator 
Check that the PWR LED is ON. This indicates that the unit is receiving +12 VDC 
power. 
 
ALARM Indicator 
Verify that the ALARM LED is OFF. This indicates that there are no alarm 
conditions present in the DAXI that would prevent normal operation or cause it to 
report status to the DSAN, resulting in traps being sent to the network management 
system. 
 
VIDEO Indicators 
Check the status of the LEDs labeled VIDEO1-VIDEO4. These LEDs represent the 
four analog program input channels on the DAXI. If a channel receives video, its 
corresponding LED is ON. 
 
ASI Indicator 
Finally, confirm that the ASI LED is ON. This indicates that the DAXI has completed 
initialization and is sending program data to the DSAN.