Cisco Headend System Release 2.7 Design Guide

Page of 124
 
Chapter 2    Monitoring SDV Alarms 
 
 
 
44 
4002915 Rev B 
 
 
SDV Server Trap 201 (C9 Hex) 
Alarm Summary: 
SDV Server Memory Threshold Exceeded 
Description: 
This alarm occurs when the SDV server exceeds the configured memory usage 
threshold that triggers a major alarm. 
Severity: 
Major 
Service Impact: 
When this alarm occurs, the SDV server is within 10% of reaching the maximum 
memory usage threshold. 
Important! If this alarm occurs frequently, you should consider upgrading the SDV 
server memory, as this condition might impact your overall SDV server 
performance. 
Check and Correct: 
Possible Cause 
Check and Correct Instructions 
SDV server loading problems. 
If loading problems periodically occur, it 
could be a result of too much load on your 
system. You may need to reduce the size of 
your service groups or upgrade your server 
memory. 
Contact the representative that handles 
your account for more information to 
arrange a memory upgrade for your SDV 
server. 
Memory leak. 
Call Cisco Services immediately for further 
assistance.