Cisco Headend System Release 2.7 Design Guide

Page of 124
 
 
SDV Redundancy Alarms 
4002915 Rev B 
59 
 
 
 
SDV Server Trap 502 (1F6 Hex) 
Alarm Summary: 
SDV Server Heartbeat Trap 
Description: 
This event is sent to the SDV Manager by a secondary SDV server (operating in 
standby mode) or by a primary SDV server (if redundancy is not implemented). 
Severity: 
Status 
Service Impact: 
If redundancy is implemented, the primary SDV server periodically issues a 
heartbeat to the backup server and not to the SDV Manager. No action is required. 
 
SDV Server Trap 504 (1F8 Hex) 
Alarm Summary: 
SDV Server Redundant Network Failure 
Description: 
This alarm occurs when the backup SDV server cannot communicate with all of its 
primary servers. 
Severity: 
Major 
Service Impact: 
A forced or automatic protection switch cannot take place with any primary server 
that the backup server cannot communicate with if this condition persists. 
Check and Correct: 
Possible Cause 
Check and Correct Instructions 
Communications problem. 
Investigate and troubleshoot the 
communications link between the backup 
SDV server and the primary SDV servers. 
Contact Cisco Services for further 
assistance.