Cisco Model D-PCG1000 PowerKEY CAS Gateway User Guide

Page of 156
749606 Rev D 
Sending DHCT Configuration 
6-19 
Base Application Tab Configuration Options,
 Continued 
Name 
This field appears at the top of the Global DHCT Configuration window. Do not 
change the value in this field. 
DHCT MAC Address 
This field appears at the top of the Addressable DHCT Configuration window. Type 
the MAC address of the DHCT that you want to configure. 
Number of Digit Entry 
This field specifies the maximum number of digits a subscriber must enter to change 
channels on the DHCT. In order for subscribers to access channels above 999, this 
field must contain 4. 
Number of LED Digits 
This field indicates the minimum number of digits to display on the LED for the 
channels. If the channel number contains fewer than this number of digits, the LED 
will display the channel number with leading zeroes. If the channel number is 
greater than this number of digits, the LED shows the full channel number. 
For example, if this field is set to 3, then the LED displays a minimum of three 
numbers when you tune to a channel: 
• 
Channel 12 will display 012 
• 
Channel 456 will display 456 
• 
Channel 1234 will display 1234 
AC Outlet Control 
This field lets you specify whether power is applied to the AC convenience outlet on 
the rear panel of the DHCT at all times or only when the DHCT is powered on. 
Select one of the following options: 
• 
On means that the AC convenience outlet has power at all times. 
• 
Switched means that the AC convenience outlet only has power when the DHCT 
is powered on. 
This field appears on this tab only if AC Outlet Control is disabled on the General 
Settings Tab.