Cisco Cisco Digital Service Access Node (DSAN) 8211 Troubleshooting Guide
Chapter 2 Hardware Installation
18
4032301 Rev A
Powering
This section provides information related to providing power to the DSAN.
Stingers
Stingers are not installed at the factory, as the customer application determines the
type of stinger required - F, N, or hardline. See the Cisco DSAN System Installation and
Operation Guide, part number 4032302 for further details.
type of stinger required - F, N, or hardline. See the Cisco DSAN System Installation and
Operation Guide, part number 4032302 for further details.
Powering Shunt Installation
The DSAN consumes approximately 106 W of power. Prior to installation, confirm
that the plant power budget can support the load of the DSAN.
that the plant power budget can support the load of the DSAN.
The DSAN can receive line power at 40 - 90 VAC through any one of its three KS
ports - Port 1, Port 2, or Port 3, as shown in the following illustration.
ports - Port 1, Port 2, or Port 3, as shown in the following illustration.
Determine which port will accept power, and install one shunt at the appropriate
location.
location.
Power Passing Shunt Installation
The DSAN can also pass line power out any of its three KS ports - Port 1, Port 2, or
Port 3, as shown above. Determine which port(s) will pass power, and install a shunt
in the appropriate location(s).
Port 3, as shown above. Determine which port(s) will pass power, and install a shunt
in the appropriate location(s).