Cisco Cisco Digital Service Access Node (DSAN) 8211 Troubleshooting Guide

Page of 114
 
Chapter 2    Hardware Installation 
 
 
 
18 
4032301 Rev A 
Powering 
This section provides information related to providing power to the DSAN. 
Stingers 
Stingers are not installed at the factory, as the customer application determines the 
type of stinger required - F, N, or hardline. See the Cisco DSAN System Installation and 
Operation Guide
, part number 4032302 for further details. 
Powering Shunt Installation 
The DSAN consumes approximately 106 W of power. Prior to installation, confirm 
that the plant power budget can support the load of the DSAN. 
The DSAN can receive line power at 40 - 90 VAC through any one of its three KS 
ports - Port 1, Port 2, or Port 3, as shown in the following illustration. 
 
Determine which port will accept power, and install one shunt at the appropriate 
location. 
Power Passing Shunt Installation 
The DSAN can also pass line power out any of its three KS ports - Port 1, Port 2, or 
Port 3, as shown above. Determine which port(s) will pass power, and install a shunt 
in the appropriate location(s).