Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
 
Applying Power to the Node 
OL-29643-02 
93 
 
 
4  The next step depends on the power path, as follows: 
IF... THEN... 
power will pass from left side of housing 
(Ports 1, 2, and 3) to right side of housing 
(Ports 4, 5, and 6) 
ensure that the AC segmentable 
shunt is installed. 
power is to be blocked between left side of 
housing (Ports 1, 2, and 3) and right side of 
housing (Ports 4, 5 and 6) 
ensure that the AC segmentable 
shunt is removed. 
Ports 1, 2, and 3 are powered from one source 
and Ports 4, 5 and 6 are powered from another 
source 
ensure that the AC segmentable 
shunt is removed. 
5  Continue to Voltage Check Procedure
 
Voltage Check Procedure 
Always check both AC and DC voltages during initial setup of the GS7000 Node. 
Follow these steps to check AC and DC voltages. 
1  Use a true-rms DVM to check for 45 to 90 V AC input voltage at the AC test point 
on the power supply module.