Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
Chapter 4    Setup and Operation 
 
 
 
120 
OL-29643-02 
 
 
2x2 and 2x4 Redundant Forward Configuration Modules 
Two primary receivers (RCVR 1 and RCVR 3) and two redundant receivers (RCVR 2 
and RCVR 4) each pair feed 2/3 output ports. 
The first pair of primary (RCVR 1) and redundant (RCVR 2) receivers feeds the right 
side of the amplifier (Ports 4 and 5/6). The second pair of primary (RCVR 3) and 
redundant (RCVR 4) receivers feeds the left side of the amplifier (Ports 1 and 2/3). 
The Status Monitor/Local Control Module switches between primary and 
redundant receivers upon loss of optical input to a primary receiver, and switches 
back to the paired primary when optical input is restored. 
Install the first set of receivers as follows: 
 
first primary receiver RCVR 1 
 
first redundant receiver RCVR 2 
Install the second set of receivers as follows: 
 
second primary receiver RCVR 3 
 
second redundant receiver RCVR 4 
 
2-way forward segmentable node 
4-way forward segmentable node 
The following diagram illustrates forward path signal flow in this module.