Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
Appendix B 
bdr Digital Reverse Multiplexing Applications 
188 
OL-29643-02 
inject the proper level into the forward output test point of a port of the RF 
launch amplifier with a reverse sweep transmitter or a CW signal generator. The 
insertion loss of all forward output test points is 20 dB (relative to corresponding 
port). 
Note: For the location of the forward output test point of each port, see RF 
Assembly
 (on page 102). 
Important: To calculate the correct signal level to inject, add the reverse input 
level (from the design print) to the insertion loss of the forward output test point. 
Formula: 
Reverse input + Insertion loss = Signal generator setting 
Example: 
Reverse input = 17 dBmV 
Insertion loss = 20 dBmV 
Result: Signal generator setting=17 dBmV + 20 dB = 37 dBmV 
Note: The ADC full-scale (100%) level for a single CW carrier is +33 dBmV. This 
is the level at which the ADC begins clipping. 
Note: The reverse attenuator (pad) and reverse equalizer in the GS7000 Node is 
selected during the reverse system design, and it is based on the drive level into 
the digital module which is determined by system performance requirements, 
type and quantity of return carriers, etc. Consult data sheet to determine proper 
operational level. 
2  Verify the level of the reverse output test point. This output level leaves the RF 
launch amplifier via the coaxial cable to the multiplexing digital module input. 
(Use an SMB connector to F-connector test cable.) 
3  Have the person in the headend refer to the headend system design and set the 
output of the bdr receiver to the specified output level. See the instruction guide 
that was shipped with bdr receiver for setup procedures.