Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
Appendix C 
Enhanced Digital Return Multiplexing Applications 
220 
OL-29643-02 
Transmitter Module Setup Procedure 
Perform the following steps to set up the reverse transmitter module(s). 
1  Open the housing according to Opening and Closing the Housing (on page 136). 
2  In the base of the housing verify that the Reverse Configuration Module installed 
in the RF amplifier is correct for your application. 
 
IF you have installed... 
THEN the installed Reverse Configuration 
Module must be... 
The minimum configuration of 
one 1:1 transmitter module in 
transmitter positions XMTR 1 
an appropriate Reverse Configuration 
Module 
Refer to the RCM Section on page 40 for 
details. 
The minimum configuration of 
one 2:1 transmitter module in 
transmitter positions XMTR 
1/XMTR 2 
an appropriate Reverse Configuration 
Module 
Refer to the RCM Section on page 40 for 
details. 
The maximum configuration of 
two 2:1 transmitter modules in 
transmitter positions XMTR 
1/XMTR 2 and XMTR 3/XMTR 4
an appropriate Reverse Configuration 
Module 
Refer to the RCM Section on page 40 for 
details. 
The maximum configuration of 
four 1:1 transmitter modules in 
transmitter positions XMTR 
1/XMTR 2 and XMTR 3/XMTR 4
an appropriate Reverse Configuration 
Module 
Refer to the RCM Section on page 40 for 
details. 
3  Verify the level of the reverse path RF signal at the RF test points on the RF 
module. Nominal level is +15 dBmV per channel. Install the appropriate value 
input pad at the REV PORT IN PAD location to give the desired signal level into 
the node. 
4  Repeat step 3 for each RF cable carrying a reverse path signal. 
5  Measure the transmitter module(s) optical output power. 
6  Check the connection of the optical connector. Make sure the optical connector is 
seated and verify fiber bend radius is greater than 1 inch. 
 
    WARNING: 
When handling optical fibers always follow laser safety precautions.