Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
 
Reverse Configuration Module 
OL-29643-02 
41 
 
Reverse Configuration Module 
Introduction 
The reverse configuration module determines the reverse path topology in the RF 
amplifier module and GS7000 Node. The input signals from four independent 
amplifier module output ports enter the reverse configuration module where they 
are combined and/or directed to one to four optical transmitters. The various 
versions of the reverse configuration module are described below. 
 
4x1 Reverse Configuration Module with Auxiliary Reverse RF Injection 
Description 
The 4x1 Reverse Configuration Module with auxiliary reverse RF injection combines 
all four reverse RF inputs (Ports 1, 2/3, 4, and 5/6) of the node and routes the signal 
to Transmitter 1. An RF signal from an external source can optionally be injected and 
coupled with the reverse RF inputs on Ports 3/6 and routed to Transmitter 1. 
The following diagram shows how this module functions. 
 
 
 
4x1 Redundant Reverse Configuration Module Description 
The 4x1 Redundant Reverse Configuration Module combines all four reverse RF 
signals (Ports 1, 2/3, 4 and 5/6) together, splits this RF signal and routes it to 
Transmitters 1 and 2. 
The following diagram shows how this module functions.