Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
Chapter 2    Theory of Operation 
 
 
 
62 
OL-29643-02 
Parameter Function 
Default 
Value 
Values Min 
Max 
Step 
Unit 
Hysteresis 
Amplitude 
Hysteresis 
Amplitude: The 
value (in dB 
relative to the 
switching 
threshold) above 
which the input 
optical power must 
raise for the switch 
to begin the 
hysteresis timer 
before restoring 
primary switch 
position. Only 
applies if Revert is 
On.  
1.0 
 
0.5 9.5 0.1 dB 
Hysteresis 
Time 
Hysteresis Time: 
The length of time, 
in seconds, that 
primary optical 
power must remain 
above the restore 
threshold before 
switch is allowed to 
revert to primary 
position. Only 
applies if Revert is 
On. 
60   
0 600 
1 sec 
Revert 
On (1) allows 
switch to revert to 
primary position 
after optical power 
restored. In Off (0), 
switch will remain 
in backup 
(non-primary) 
position. 
On(1) Off(0) 
On(1) 
na na na na 
Primary 
Optical 
Input 
Selects the primary 
optical input 
PathA(0) PathA(0) 
PathB(1) 
na na na na